Earthquake-resistant reinforcement brackets(1*4) - メーカー・企業と製品の一覧

Earthquake-resistant reinforcement bracketsの製品一覧

1~2 件を表示 / 全 2 件

表示件数

FIT GATE Construction Case: FIT GATE

The dimensions are W14m × D6.1m × H3.5m! Installation case with body mounting, completed in 2 days with 3 workers.

We would like to introduce a case where we delivered the "FIT GATE." The dimensions are W14m × D6.1m × H3.5m, with the structure installed, taking 2 days with 3 workers. It features partition walls made of reinforced glass FIT, a garage roof, and corrugated GL steel sheet roofing. There is an existing foundation on the north side. On the back side, there are middle windows and a side entrance sliding door. Please feel free to consult us when you need assistance. 【Case Overview】 ■Dimensions: W14m × D6.1m × H3.5m ■Required Days: 2 days with 3 workers *For more details, please refer to the related links or feel free to contact us.

  • Gates, walls and fences
  • Fences and gateposts
  • shutter

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

Seismic reinforcement hardware "FIT Power" Type 14 for concrete block walls, etc.

Can be installed even in narrow areas like densely populated urban residential areas! Seismic reinforcement brackets that can achieve seismic retrofitting in a short period with minimal construction.

"FIT Power" is a seismic reinforcement fixture such as a concrete block wall that serves as a substitute for retaining walls. It keeps the maximum protrusion of the site-side angle post to about 65mm, allowing for passage even after installation, making it a convenient design for narrow lots and densely populated residential areas. Additionally, it can be tightened by a single worker from the site side, enabling a reduction in construction time. The FIT Power Type 14 is compatible with block walls of H1, 400mm from the road surface. *We also have models available for block walls ranging from H1,200 to 1,800mm. 【Features of FIT Power】 ■ Lock bolt pile foundation method - Ground friction force is seven times the weight - Shortened construction period and cost reduction ■ Round head bolts prevent free spinning ■ Design that maintains convenience even in narrow spaces - Residents can pass through even after installation - Component weight manageable by one person ■ Demonstration experiments conducted under the guidance of the Faculty of Engineering, Gifu University ■ Patent obtained as a "reinforcement structure and reinforcement member for walls" ■ Certified as a recommended disaster prevention product by the Japan Disaster Prevention Safety Association *For more details, please refer to the PDF materials or feel free to contact us.

  • Earthquake-proof and vibration-damping equipment

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録